ABOUT ME

-

Today
-
Yesterday
-
Total
-
  • Autumn Solar User Manual
    카테고리 없음 2020. 2. 16. 12:36

    This refers to your POOL sensor that reads your pool water temperature. There are 3 possible answers for the error code:Is the Pool sensor cable reversed with the roof sensor?Reverse sensor wire back to the correct positionsCheck the sensor cable for any damage including the wires that go into the connection to the controller. Repair cable if damagedShort circuit in digital sensor that sits in the pipe / water. The Sensor will need to be replaced with a new sensor. How to change over a Pool / Pipe Sensor. This refers to your Roof sensor that reads your roof temperature. There are 3 possible answers for the error code:Is the roof sensor cable reversed with the pool sensor?Reverse sensor wire back to the correct positionsCheck the sensor cable for any damage including the wires that go into the connection to the controller.

    1. Autumn Solar User Manual Pdf
    2. User Manual Template
    3. Autumn Solar Controller User Manual

    Repair cable if damagedThere may be a short circuit in digital sensor that sits on your roof. The Sensor will need to be replaced with a new sensor. How do I purchase a new / replacement Roof sensor? Settings mode is for setting the unit into time-clock operation.When you select this option you will be asked if you wish to use the clock feature(CLK?

    ON/OFF).If you select OFF then the controller will not work as a time-clock model and will prevent starting the pump to sample at night based on a sequence of events.If you select ON you will be prompted to set the time of day, the controller will work in time-clock mode and the solar pump is prevented from starting outside of the set hours (unless tropical mode is selected). Set the time of day in 24 hour format, note there is an AM/PM indication to avoid incorrect settings.

    Seconds are automatically set to zero.Once the time is set select the START hour from 6am till 12 noon, default is 9am which means the solar pump cannot start before 9am.Now select the END hour from 15:00 (3pm) until 21:00 (9pm), default is 19:00 (7pm) which means the solar pump will stop at 7pm.You can also download your controller manual for step by step instructions on our. How do i change the time on my SL6 Deluxe? Press the up and Down arrows on the controller at the same time till the screen flashes and goes blank then let go of the buttons.You will have an ‘M’ light flashing, this is the minutes of the controller and you can adjust accordingly with the up and down arrows to the correct time then press select.You will now have a ‘H’ light flashing.

    This is the hours of the controller and again you can adjust accordingly with the up and down arrows to the correct time then press select.The controller is in 24 hour time. Therefore 1pm should show as 13:00. Why is there no power to the display of my controller? A few quick steps to determine the issue:.

    Is the power point faulty? Test the power point with a known working appliance (like a phone charger or hair dryer). If the power point is operational;. Check the controller with by plugging this into another power point.If there is still no display then the controller will need to be returned to Sunlover Heating to be reviewed and repaired. Please return your controller along with the to Sunlover Heating. The Controller is on, but the pump is not working and solar conditions are good. A few quick steps to determine the issue:.

    Is the pool temperature less than 8°C cooler than the roof temperature. If so the solar will not turn on until this differential is reached. Check the pump is plugged into the base of the controller;.

    Set controller to Manual mode – does this turn the pump on?. Test the pump by plugging into a different power point and turning on. Does this turn the pump on? If it doesn’t, then the pump may be the problem.

    Contact the Service Department at Sunlover Heating. Check controller power output (where your pump was plugged in) by plugging in working appliance (i.e power tool or small appliance) into the bottom of the controller to see if it runs – if not the controller may be the problem. Please return your controller along with the to Sunlover Heating. My Solar seems to turn on at night. Why does it happen? The message “Waiting To Sample” is usually preceded by the message “Pool Temperature Reached”.These are information messages informing that the pump has been on but is now off because the set temperature has been achieved (that is“Pool Temperature Reached”) and that it will not check the pool temp again for around 4 hours (that is“Waiting To Sample”) because the pool is unlikely to loose temp for some time.

    The only way to reset the controllers memory of the pool temperature is to turn off the controller for 10 seconds. How do I return my controller for repairs?.

    Ensure the pump is plugged directly into your solar controller and not into an independent power point;. The controller should be in Summer or Winter mode and not manual;. Turn the solar controller off for 3 minutes and allow the programming to reset in both the controller and the pump.If the pump continues to run, the controller may be experiencing an internal fault.Please return your controller along with the to Sunlover Heating.You can also download your Pump manual Here:.

    Autumn solar user manual

    Why wont the pump turn on? A few quick steps to determine the issue:. If you have an SL6 Deluxe Controller, your time settings may not be accurate. Check that the time is set to the correct hour and minute (24 Hour time). Check the pump is plugged into the base of the controller;. Are solar conditions good?

    There must be at least an 8 degree difference between the pool temperature and the roof temperature for the solar to turn on. Set controller to Manual mode – does this turn the pump on?. Test the pump by plugging into a different power point and turning on. Does this turn the pump on? If it doesn’t, then the pump may be the problem. Contact the Service Department at Sunlover Heating. Check controller power output (where your pump was plugged in) by plugging in working appliance (i.e power tool or small appliance) into the bottom of the controller to see if it runs – if not please the controller may be the problem.

    Please return your controller along with the to Sunlover Heating.You can also download your Pump manual Here:. How do I prime my pump? Fill strainer housing with water to suction pipe level. Never operate the pump without water.

    Water acts as a coolant and lubricant for the mechanical shaft seal.Open all suction and discharge valves, as well as air bleed (if available) on filter. (The air that is to be displaced from the suction line must have someplace to go).Turn on power and allow a reasonable time for priming. Five minutes is not unreasonable. (Priming time depends on suction lift and horizontal length of suction piping).You can also download your Pump manual Here:. Why wont my Pump Motor start?. Make sure pump strainer/housing is filled with water, and that cover gasket is clean and properly sea-ted.

    If you have a pin hole leak you may need to purchase a Solar Repair Kit.Isolate affected solar tube and cut the tube at leak. Using water based lubricant, lightly spray area with lubricant and insert small joining barb into each end of the tube pushing them firmly together.Please call your nearest Sunlover Heating office on 1800 815 913 to purchase a repair kit.

    Autumn Solar User Manual Pdf

    Payment can be completed over the phone via MasterCard or Visa. I have a big spray of water coming from my solar. How can I repair this myself? If you have a tear Leak (where material has damage bigger than a pin hole) you may need to purchase a Solar Repair Kit.Isolate affected solar tube and cut to remove damaged section. Using water based lubricant, lightly spray in solar tube with lubricant and insert small joining barb into each end of the tube pushing them firmly together. Place small section of tubing (supplied in kit) and repeat process.Please call your nearest Sunlover Heating office on 1800 815 913 to purchase a repair kit. Payment can be completed over the phone via MasterCard or Visa.

    One of my Manifolds has broken. How can I repair this myself? If a barb at the black molded manifold has broken, you may need to purchase a Solar Repair Kit.Remove the affected barb and clean area.

    Use a 5mm drill bit and carefully drill out the hole. Using the grey grommet (supplied in repair kit) gently place into the hole. Using water based lubricant, lightly spray area with lubricant and insert small joining barb. Then join the solar tube back onto the other end of the joining barb. If the broken barb cannot be removed from the tube, cut the appropriate length off and place barb into tube and connect to manifold.You can also choose to replace the entire manifold. This will need to be purchased from Sunlover Heating along with a few other spare parts.Please call your nearest Sunlover Heating office on 1800 815 913 to purchase a repair kit or spare parts.

    User Manual Template

    Payment can be completed over the phone via MasterCard or Visa. How Do I place a service call? If the Vacrel leaks it may have some type of foreign material under the silicone rubber.

    Ie Stick, leaf, spider etc.To clean this unit: Unscrew the Valve body from the main body of the Vacrel. (grip pointsincluded on this part) Simply clean out the Underside of the umbrella lip (soft rubber) on the valve and remove any foreign material. Replace the valve body ensuring that the O-ring is still in place Replace Vacrel onto your solar systemShould you continue having an issue with leaks on the valve please contact your local Sunlover Heating Office during business hours for assistance.Pool Blankets & Rollers. How to install and trim a solar pool blanket?

    Before trimming the cover, lay it bubble side to the water and allow to rest for a few hours so any packing creases can settle and flatten.Using the shape of your pool as your cutting template, take a pair of SHARP household scissors and trim the cover approximately 3 to 5 cm over the edge of your pool and up the tiles ensuring this remains below the rim of the pool.The cover should create a dish like effect with the edges curved up the tiling, preventing any debris from entering the pool.It is also suggested to cut a small flap for your skimmer box. Any debris caught on the blanket can easily be hosed into the skimmer box keeping your pool clean and saving you money on unnecessary filter maintenance.We highly recommend completing this procedure on a sunny day with someone to assist with holding the blanket in position.TAKE CARE – IT IS EASY TO CUT TOO MUCH!. How do I set up my Pool Blanket Roller. A bleeder pipe/Equaliser tube is used to allow the roof system to drain while the solar is not operating.

    This is installed on the pipe work up to the roof (below the eve) connecting supply and return pips.To install the equaliser tube. Drill one 9mm hole onto each of the 40mm pipes. Insert a grommet into each hole.

    Using one tube of the solar absorber, push a joining barb into either end and push both ends into the grommets and sleeve.An Example of the Install –WARRANTY. I believe i have a warranty issue. What do i need to do?

    Autumn Solar Controller User Manual

    DELUXE COVERGreen / Black Binding SUPREME COVERTan / Black BindingMade from tough polyethylene fabric. Tough, durable material. Won’t crack, split or tear from the cold!. Lightweight – Easier to put on and take off the pool than heavier, bulkier vinyl covers. Takes up less room to store, too!.

    Reinforced seams that last longer! Won’t rip, fray or come apart. Made from the best material with the highest concentration of UV stabilizers to ensure your cover will last for years. Available in Deluxe 4 ft overlap or Supreme 4 ft overlap. IMPORTANT: The 'No Diving' and other Warning signage provided must be installed on each pool as indicated in the instructions provided.NOTE: In some photos of the pools in the brochure (or web site), the 'No Diving' and other Warning signage may not be visible, such Warning Signage must be installed as indicated in the instructions provided.Hollowell Industries, Inc. Stands behind every product we produce pursuant to those representations which are stated in our written warranties. Your dealer/builder/installer/contractor is an independent business and not an agent/representative or employee of Hollowell Industries, Inc.

    We cannot and do not accept any responsibility for any representations, statements or contracts made by any dealer/builder/installer or contractor.